In the field of ultrasonic transducers, circular piezoelectric ceramics provide strong impetus for the widespread application of ultrasonic technology due to their efficient energy conversion ability. Whether it is ultrasound diagnosis in the medical field or non-destructive testing in the industrial field, circular piezoelectric ceramics play a crucial role.
Circular piezoelectric ceramics have become an indispensable and important material in the development of modern technology due to their unique properties and wide application fields. With the continuous progress of technology, circular piezoelectric ceramics will undoubtedly demonstrate their unique value and charm in more fields.
Specification | Dimension (mm) |
Radial frequency (KHz) |
Capacitance (±12.5%) pF |
Dielectric dissipation factortanδ (%) |
Impedance (Ω) |
Electromechanical coupling coefficientKr | Mechanical quality factor (Qm) |
PLS-QXJP3030 | Φ30×3.0 | 66.7 | 2730 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP3530 | Φ35×3.0 | 63 | 3100 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP3865 | Φ38×6.5 | 59.9 | 1580 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP4530 | Φ45×3.0 | 50 | 5100 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP4535 | Φ45×3.5 | 50 | 4700 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP5030 | Φ50×3.0 | 46 | 5800 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP5035 | Φ50×3.5 | 46 | 6300 | ≤0.3 | ≤15 | ≥0.55 | 500 |
PLS-QXJP5050 | Φ50×5.0 | 46 | 4150 | ≤0.3 | ≤15 | ≥0.55 | 500 |